UT-R Extreme

Undermount refrigeration for airport applications
A highly specialised model for airport operators, the UT-R Extreme is designed for scissor lift trucks, enabling protection of airport catering and other goods in the highest ambient temperatures.

Tech specs

UT-SERIES UT-R EXTREME
Refrigeration Capacity High Ambient Temperature (55°C)
Capacity on engine power 0°C
W
7 100
Capacity on engine power 20°C
W
12 900
Features
Noise level
101 dB(A) guaranteed sound power level
Controller
General
TSR-3
Compressor
Model
X430 C5
Displacement
cm3
489
Number of cylinders
4
Generic (Boxlength, Refrigerant, ...)
Refrigerant
R-452A
Weight
Condenser
kg
479
Installation kit
kg
10.8
Evaporator
kg
63.5
Defrost
Defrost
Automatic hot gas defrost
Airflow
Volume @ 0 Pa static pressure
m3/hr
3 350
Unit Dimensions
E-type Evaporator height
mm
302
E-type Evaporator width
mm
1 615
E-type Evaporator depth
mm
638
Condenser Height
mm
636
Condenser Width
mm
1 608
Condenser Depth
mm
721
Engine
Model
TK 376
Rating
kW
14.6
Maintenance Interval
hrs
2 000
Number of cylinders
3
Displacement
1 116
Electrical Stand by Motor
Voltage / Phase / Frequency
230-400V / 3 Ph / 50-60Hz
Rating
kW
7.5
Noise
Road Mode
dB(A)
73.4
Electric Standby
dB(A)
63.4
Refrigerant
Charge
kg
4.6